B. J. Wolfe Enterprises, Inc.                             
Temperature Measurement Control & AC/DC-DC/DC Power Supplies
  SearchHomeAbout UsTemperaturePower SuppliesE-Mail              800/554-1224 or 818/889-8412
  AthenaDoricBenchtopCalibratorHandheldsHot PlatesHook-Up WireMarlinMeasSpecialtiesPartlowPower Controller
  ProbesStrain GagesTemp AccessoriesTempilThermistorsThermocouplesWatlow/TC-WireA P DA P XArtesynC D IChassis / PC
  Computer PrdtsConversionDevicesDeskTop/WallInt'l Power DCInt'lPwrDeviceKagaLinearsMartek PowerMelcherPC Mount-ACPower-OneTaxanVolgen America


MGO Metal Sheathed Cable
mgo.jpg (8037 bytes)

Available:  Sheath Description, Applications, and Accessories:
            Connectors and Tube Adaptors
            OD:  .010, .020, .032, .040, .063, .090,
                   .125, .188, .250, .313, .375, .555     

Part Number

ANSI Type

Sheath O.D.

Sheath Material

MGO Purity

B & S Gauge

Wall Size

402-2116 K .010 304 99.4 44 .0015
.
401-1101 J .020 600 99.4 38 .003
401-2101 K .020 600 99.4 38 .003
402-1101 J .020 304 99.4 38 .003
402-2101 K .020 304 99.4 38 .003
402-3101 T .020 304 99.4 38 .003
.
401-2101 K .032 600 99.4 34 .004
402-1102 J .032 304 99.4 34 .004
402-2102 K .032 304 99.4 34 .004
.
401-1103 J .040 600 99.4 32 .006
401-2103 K .040 600 99.4 32 .006
402-1103 J .040 304 99.4 32 .006
402-2103 K .040 304 99.4 32 .006
402-3103 T .040 304 99.4 32 .006
402-4103 E .040 304 99.4 32 .006
404-2103 K .040 316 99.4 32 .006
.
401-1104 J .063 600 99.4 28 .009
401-1504 J .063 600 96.0 28 .009
401-2104 K .063 600 99.4 28 .009
401-2504 K .063 600 96.0 28 .009
401-5104* R .063 600 99.4 30 .009
401-6104* S .063 600 99.4 30 .009
402-1104 J .063 304 99.4 28 .009
402-1504 J .063 304 96.0 28 .009
402-2504 K .063 304 96.0 28 .009
402-3104 T .063 304 99.4 28 .009
402-4504 E .063 304 96.0 28 .009
404-1504 J .063 316 960 28 .009
404-2504 K .063 316 96.0 28 .009
.
401-2505 K .090 600 96.0 25 .012
.
401-1507 J .125 600 96.0 22 .017
401-2107 K .125 600 99.4 22 .017
401-2507 K .125 600 96.0 22 .017
401-3507 T .125 600 96.0 22 .017
401-4507 E .125 600 96.0 22 .017
401-5107* R .125 600 99.4 24 .020
401-6107* S .125 600 99.4 24 .020
401-8107 N .125 600 99.4 22 .017
402-1107 J .125 304 99.4 22 .017
402-1506 J .125 304 96.0 22 .017
402-2107 K .125 304 99.4 22 .017
402-2507 K .125 304 96.0 22 .017
402-3507 T .125 304 96.0 22 .017
402-4507 E .125 304 96.0 22 .017
403-2507 K .125 310 96.0 22 .017
404-1107 J .125 316 99.4 22 .017
404-1507 J .125 316 96.0 22 .017
404-2107 K .125 316 99.4 22 .017
404-2507 K .125 316 96.0 22 .017
404-3507 T .125 316 96.0 22 .017
404-4107 E .125 316 99.4 22 .017
404-4507 E .125 316 96.0 22 .017
.
401-1508 J .188 600 96.0 19 .025
401-2108 K .188 600 99.4 19 .025
401-2508 K .188 600 96.0 19 .025
401-3508 T .188 600 96.0 19 .025
401-4508 E .188 600 96.0 19 .025
401-8108 N .188 600 99.4 19 .025
401-1108 J .188 304 99.4 19 .025
402-1508 J .188 304 96.0 19 .025
402-2108 K .188 304 99.4 19 .025
402-2508 K .188 304 96.0 19 .025
402-3508 T .188 304 96.0 19 .025
402-4508 E .188 304 96.0 19 .025
403-2508 K .188 310 96.0 19 .025
404-1108 J .188 316 99.4 19 .025
404-1508 J .188 316 96.0 19 .025
404-2108 K .188 316 99.4 19 .025
404-2508 K .188 316 96.0 19 .025
404-3508 T .188 316 96.0 19 .025
404-4108 E .188 316 99.4 19 .025
404-4508 E .188 316 96.0 19 .025
.
401-1511 J .250 600 96.0 16 .033
401-2111 K .250 600 99.4 16 .033
401-2511 K .250 600 96.0 16 .033
401-8111 N .250 600 99.4 16 .033
402-1111 J .250 304 99.4 16 .033
402-1511 J .250 304 96.0 16 .033
402-2111 K .250 304 99.4 16 .033
402-2511 K .250 304 96.0 16 .033
402-3511 T .250 304 96.0 16 .033
402-4511 E .250 304 96.0 16 .033
403-1511 J .250 310 96.0 16 .033
403-2511 K .250 310 96.0 16 .033
404-1111 J .250 316 99.4 16 .033
404-1511 J .250 316 96.0 16 .033
404-2111 K .250 316 99.4 16 .033
404-2511 K .250 316 96.0 16 .033
404-3511 T .250 316 96.0 16 .033
404-4111 E .250 316 99.4 16 .033
404-4511 E .250 317 96.0 16 .033
.
401-1512 J .313 600 96.0 14 .041
401-2512 K .313 600 96.0 14 .041
401-2513 K .375 600 96.0 13 .052
402-1513 J .375 304 96.0 13 .052
404-2513 K .375 316 96.0 13 .052
401-2515 K .500 600 96.0 11 .070
Specifications subject to change without notice.

Wire Selection Guide

To Order Special Limits of Error, Add Suffix -SP

Alloys: 600-Maximum Temperature: 1212°C (2150°F) Most widely used thermocouple sheath material. Good high temperature strength and resistance to: corrosion, cracking, chloride-ion stress, and oxidation in high temperature. Do not use in sulfur bearing environments. Good in nitriding environments.

304SS-Maximum Temperature: 900°C (1650°F) Most widely used in low temperature sheath material. Extensively used in food, beverage, chemical, and other industries where corrosion resistance is required. Subject to damaging carbide precipitation in 482°-871°C (900°-1600°F) range. Corrosion resistant sheath material.

310SS-Maximum Temperature: 1150°C (2100°F) Mechanical and corrosion resistance, similar to but better than 304SS. Very good heat resistance. This alloy contains 25% CR, 20% Ni. Not as ductile as 304SS.

316SS-Maximum Temperature: 900°C (1650°F) Best corrosion resistance of austenitic stainless steel grades. Widely used in the food and chemical industry. Subject to damaging carbide precipitation in 482°-871°C (900°-1600°F) range.

Standard Purity 96% (min) Magnesium Oxide This insulation is similar to high purity Mgo(1) except it should be used in applications below 2000°F because of the impurity levels. This insulation should not be used with platinum or in nuclear applications.

High Purity 99.4% (min) Magnesium Oxide Low impurity levels make this insulation very useful for all thermo- couple calibrations up to 2500°F. Above 2500°F we recommend using Berylium Oxide insulation because of Mgo's low Resistivity. This material meets the requirements established in ASTM E-235-82.

Stripping-It is recommended .032" or smaller that it be ordered factory stripped. Material larger than .125" diameter can be stripped in a lathe with a suitable tool bit or lathe-mounting stripping tool. It is also possible to strip larger sizes of XacTpak® by using a hack saw to make a ring cut through the sheath at the desired distance from the end. Hammering the severed portion of sheath at several places will break up the insulation allowing the sheath to be slipped off. After stripping, the exposed conductors should be sand blasted or cleaned with emery cloth. The exposed ends should be resealed immediately after completions of the stripping operation.

Wire Selection Guide

Strippers, Connectors, and Tube Adaptors are available from BJWE.

PDF Data Sheet

XacTpak® a registered trademark of Watlow.

ANY STATEMENT AS TO PRODUCT COMPLIANCE WITH APPLICABLE LAW (INCLUDING WITHOUT LIMITATION, THAT PRODUCTS ARE Pb-FREE OR RoHS COMPLIANT) IS AS PROVIDED BY ITS SUPPLIERS, AND B. J. WOLFE ENTERPRISES DOES NOT WARRANT ITS ACCURACY AND WILL NOT BE LIABLE FOR ANY ERROR WITH REGARD TO SUCH INFORMATION.  CUSTOMER USES THE INFORMATION AT ITS OWN RISK.  PRICES SUBJECT TO CHANGE WITH NOTIFICATION.

If you require additional information contact us:   

(800) 554-1224, (818) 889-8412, Fax (818) 889-8417 or email:  info@bjwe.com
Home   |  About Us  |  Disclaimer  |  Privacy Policy