Selection Guide | ||
CB150D Data Sheet & CB225T Data Sheet | ||
Specification subject to change without notification. | ||
Environmental Screening | ||
M-Grade Environmental Screening | ||
Stabilization Bake | +125°C for 24 hours Similar to MIL-STD 883, M1008.2, Condition B | |
Temperature Cycling | 10 Cycles -55°C to +125°C, (Transition Period 5°C/min.), Similar to MIL-STD-883, M1010, Condition B | |
Burn-In | 160 Hours @ +85°C min. with Vin=28Vdc & Output Full Load | |
Final Testing | ||
I-Grade Environmental Screening | ||
Burn-In | 16 Hours @ +85°C min., with Vin=28Vdc and Output at Full Load | |
Final Testing |
Dual and Triples Output Voltage & Output Current | |||
Nominal Output Voltage | Output Current (Amps) |
Configure Part Number | |
2 | 15.0 | Part numbers for the CB150D (dual) & CB225T (triple) are configured |
|
3.3 | 15.0 | ||
5 | 15.0 | ||
5.2 | 14.5 | ||
12 | 6.3 | ||
15 | 5.0 | ||
24 | 3.2 | ||
28 | 2.7 | ||
Sample Configuration: CB150DM/5/15-C-D, CB225TM/5/15/24-C-D |